Tag Archives: plc

300plc master and 200PLC as slave station group DP network related issues

A 300PLC CPU 314C-2DP the master station and three sets of 200plc CPU 226 DP network from a station group, communication module is EM277. Preliminary 300plc and 200plc Group DP network hardware is configured to download properly, but when more than two 200plc network, after downloaded into 300 (OB blocks without programming, hardware configuration only) […]

SMART PLC S7-200 communication portal common knowledge to answer

1th: communication is what? Essentially communication ports around the combination of high and low level, to achieve 0 1 codes delivered between two devices, 0 is low level, 1 is high. Now, if I have a PLC and inverter communication, then the fact is hardware and cables throughthe communications port of the inverter produces combinations […]

Five standard programming languages for PLC

PLC user program is designed according to the process control requirements of the control system, the design of the PLC programming language. Industrial control programming language standard (IEC1131-3) based on the international electric commission. PLC programming language includes the following five kinds: ladder diagram language (LD), instruction list language (IL), function module diagram language (FBD), […]

STEP 7 using the network settings configuration DP master systems

Network settings can also be used to distribute I/O configuration. With the View →with DP Slaves/IO Devices on the network to browse displays or hides the DP Slave. The DP master system configuration requires the following components: PROFIBUS network (if it does not exist, drag the object from the network directory in PROFIBUS networks to network In the envelope window). DP master station of the workstation (if it does not exist, drag objects from the network directory for a Windows workstation to the network, Open workstation with hardware configuration tool and select the DP master station, which can be integrated in the CPU can also be a Independent modules). From the DP master station connection to PROFIBUS networks (in a hardware configuration tool, select the network, or DP master station network configuration double click on the network connection, and then “hold“ and drag to a PROFIBUS network ). In the network window, select that you want to configure from the DP master station. “PROFIBUS DP” under network objects list found in the subdirectories and DP Slave station, drag it to the network window, fill in the Properties window that pops up. Select DP Slave, and then use Edit → Open set the parameters Object to DP Slave. The hardware configuration is started. Now set the user data address, select I/O module or module from the station. If you have previously created an intelligent DP Slave station, you can connect it to a network. Directories in the network object can be “Configured stations (configured workstation)“ find intelligent type of the DP Slave, which together with the DP master station of your choice and drag the network window and then fill in the Properties window pops up (and identical in hardware configuration tool). First select the master or the master station of the slave, with the View → Highlight→ Master System can stress the node configuration DP master system. With the View → Rearrange, can be connected to the optimal allocation of DP DP Slave on the primary station.

STEP 7 connect configuration

Connections describe communication between two devices. In the following case, the connection must be configured: Established between the two SIMATIC S7 S7 communication (“communication via aconfiguration connection“). Communication partners are not SIMATIC S7. Note: for programming and debugging, programming the device directly connected online to the MPI network, does not require configuration connection. If you are programming the device reached the configured on other connected nodes on the network, it must be configuration, programming devices of connection: network workstation the double-click to select PG/PC in the object list; in the network window, double click to open PG/PC; select the interface and configure it to a network. 1. Join tables Communications connection configuration in the connection table. Condition has created a project with all workstations that need to Exchange data, and has a communications module has been configured to network. CPU container objects in the Connections (connections) indicates that the connection table, double-click on it to start the network connection, as in the project on the network, double-click in the container. The connection configuration, network configuration, select a S7-400 CPU. In the network window is the connection in the lower part of the table (as shown in table 2-1,if you do not see the table, position the mouse pointer on the bottom edge of thewindow, widen the window edge after deformation the mouse pointer). Insert → New Connection or double-click on an empty row to enter the new communication connection. For each “active“ CPU to create junction table. Please note, you cannot create a junction table for S7-300 CPU, S7-300 CPU only as S7 connection in the “passive“ partner. In the “Insert New Connection (insert a new connection)“ in the window “Station (station)“ and “Module (module)“ dialog box, select the communication partners (as shown in Figure 2-6), stations and modules must already exist. This window also determines the type of communication. Communications connection configuration If you want to set more communication features, activate the check box “Before inserting:display properties (insert: display characteristics)“. All the data connections table includes the configuration connection. If you want todisplay more clearly, select View → View → Display Columns and Optimize Column width. 2. Connection ID The number of connections associated with the CPU. STEP 7 define a connection IDfor each connection and each partner. When using a communication block in your program, it is necessary to use this definition. You can modify the local ID (the module ID of the connection being opened). If thecommunication block has finished programming, and local ID to define the connection, it is necessary to use this function. Enter a hexadecimal number as a new local ID. This number must be in the following range, depending on the connection type, and there is no use: S7 connection, a range of values is 0001H~0FFFH S7 ‘s S7 connection can be mounted (S7-300), a range of values is 0001H~008FH For point to point connections, a range of values is 1000H~1400H Changing partners (communication objects) when the ID, enter the partner connection table changes after the local ID of the CPU (which is local): select the connectionline and choose Edit → Object Properties. If STEP 7 does not enter a partner ID, thenit is a one-way connection (see below). 3. Partner This column displays the connection partner. If you […]

STEP 7 load connection data

To activate a connection, you must save and compile the connection table is loadedinto PLC (all the all loaded into the table “initiative“ in the CPU). Do the above conditions: the user is already in the network window, and the connection table is visible. Programming device is a node in the network, with communication capabilities that will be loaded into the table module is also on the network. All child nodes of the network node is assigned a separate address. Connected data modules will be loaded in STOP mode. PLC → Download → in current project … Connection and configuration data to the read-write module. Depending on the selected objects and select menu commands,choose between the following: → The Selected Stations (selected workstation) → Selected and Partner Stations (selected workstation workstations and partners) → Stations on the Subnet (a workstation on the network) → The Selected Connections (the connection you selected) → Connections and Gateways (connection with the gateway) Programmable module you want to remove all the connections, just an empty tableto the relevant module is loaded. Compiled connection data Blocks (block) container System data (System data) partof it. CPU to start after system data linking the data to the module with communications capabilities. Online through the MPI runtime, programming device does not require additional hardware. If you want to connect the PC to the network or to connect the programming device to the Ethernet or PROFIBUS, needs the appropriate interface module. InWindows Control Panel (Windows Control Panel) in the “Set PG/PC Interface (sets the PG/PC interface)“ tool to the module set parameters.

STEP 7 of the network transformation

If your programming device is connected to a network, it is able to reach all the other nodes on the network. For example, a connection point for all S7 workstation that is connected to an MPI network programming and debugging. If another network (such as PROFIBUS) attached to an S7 station, programming devices can reach the workstations on the network. The prerequisite of this is network workstation with a routing of the conversion function, that is, to guide the transformation of message framing. In the network configuration when compiled, automatically convert network workstation generates a routing table that includes all of the necessary information. All communication partners must be in a S7 project of equipment in the network configuration, and they must be provided about which networks can reach which workstations and network transformation “knowledge“. If you want to use programmable devices from one connection point to all nodes inthe network, the connection point must be configuration. Enter a “placeholder“, that is, network configuration from the network network object in the directory PG/PC workstation. In the programmable devices on each network you want to connect, forPG/PC configuration. At run time, the programming device is connected to a network, and then select Assign PLC → PG/PC, the programming interface of the device changes to network configuration settings. Prior to the programming device disconnected from the network,select Undo PLC → PG/PC Assignment. If you want the programming did not include a required project online, S7 network ID is required when entering the network. The ID consists of two numbers: the project number and subnet number. Can get the network number in the network configuration: select the network, and then in the “General“ tab, select Edit → Object Properties.