Panasonic PLC high speed pulse output

1. DT90052 is just a register for a high-speed counter or high-speed pulse output flag.
H110 MOV DT90052, which means that the CH0 pulse channel is close to the origin signal and encounters near-origin deceleration when returning to the origin.

2.H100 MOV DT90052, which means that the CH0 pulse channel is written to 0 immediately, and preset.

3.H101 MOV DT90052, which means that the CH0 pulse channel near-origin signal is invalid, pulse process value DT90349, DT90348 double word soft reset–clear.

H100 MOV DT90052,, indicates that the CH0 pulse channel is written to 0 immediately, and preset.

4.H1101 MOV DT90052, which means that the CH1 pulse channel near-origin signal is invalid, pulse process value DT90353, DT90352 double word soft reset–zero.

H1100 MOV DT90052,, means that the CH1 pulse channel is written to 0 immediately, and preset.