STEP7-Mirco/WIN software project management

1 print
 
(1.) printing method of program and project documents


Print program and project documents in the following way:
Click the print button.
Select the menu command file then print.
Press the CTRL + p shortcut key combination.


(2). network and print a single item
Following a single block printed a series of network, or from a single symbol table or figure printed a series of rows:


1, select the appropriate check box, and use the range field specifies the print element.


2, select a range of text, the network, or line and select print. You should check the following items: the print order/ write correctly in the frame Editor; scope items box, select the correct POU (if applicable), POU scope free right of the entry box radio button; scope shows the correct number in the entry box.


2 replication project


Can be copied in STEP 7-Micro/WIN project 32: text, instruction or data domain, a single network, multiple adjacent networks, POU in all networks, rows or columns, or the entire state diagram, symbol table rows or columns, or the entire symbol table, a data block. But not copies or multiple noncontiguous networks. Cannot bulk copy data from one local variable table and paste it to another local variable tables, readonly l memory assignment for each table must be unique.


Cut, copy, or delete the network as a whole in LAD and FBD program, you must place the cursor in the network header.


3 importing files


From STEP 7-Micro/WIN 32, an importer, you can use the import command to import ASCII text files. The import command does not allow you to import the data. Open a new or existing projects, you can use file import command.


If you import OB1 (main program), will delete all existing POU. Then, as OB1 and as ASCII text files, all part of routine or interrupt program ASCII data creates an organizational unit.
If you import only subroutines and interrupts the program (not defined in the ASCII text file of the main program), POU defined in the ASCII text file will replace all existing corresponding number from STEP 7-Micro/WIN project 32 POU (if STEP 7-Micro/WIN project 32 is not empty). Existing STEP 7-Micro/WIN project 32 main program and is not defined in the ASCII text file of all STEP 7-Micro/WIN 32 POU is retained.


If the STEP 7-Micro/WIN 32 projects may include OB1 and SUB1, SUB3 and SUB5, and from an ASCII text file import, SUB2, SUB3 SUB4. Final project: OB1 (from STEP 7-Micro/WIN project 32), SUB1 (from STEP 7-Micro/WIN project 32), SUB2 (from ASCII text file), SUB3 (from ASCII text file), the SUB4 (from ASCII text file), SUB5 (from STEP 7-Micro/WIN 32 projects).


4 exporting files


Editor for the export program to STEP beyond 7-Micro/WIN 32, you can use the export command to create the ASCII text file. The default file name extension for awl , you can specify any file name. Program only successfully compile can execute export operations. Export command does not allow you to export data. Open a new or old projects to use the export function.


With the export command by the following methods to export existing POU (main program, subroutine, and interrupt routines)


If you export a OB1 (main program), all existing project POU as ASCII text files, and exporting.


Export routine or interrupt routines, currently open for editing a single POU exported as ASCII text files.